SN 9424

Downlights for recessed mounting

INOTEC SN 9424 downlights are made of high-quality powder-coated die-cast aluminium. A highly efficient, latest-generation power LED combined with excellent thermal management ensures a lamp luminous flux of more than 160lm/W. The multi-chip LED used also offers greater safety. With INOTEC FUSION CPS and CLS emergency lighting devices, even the failure of a single chip can be detected.

  • Cost-effective implementation in fire protection or concrete ceilings

  • Easy installation

  • State-of-the-art lighting technology

Flush-mounted installation for a wide range of applications

The compact design of the 24 V control gear allows the SN 9424 luminaire series to be easily installed in a wide range of standard device connection boxes. This means that even challenging installation situations can be handled efficiently.

The luminaires, including the LED drivers, can be placed completely inside the box, ensuring particularly clean and safe installation. Users also benefit from high compatibility: the SN 9424 offers the same lighting technologies that are already used in the proven SN 9400.

 

< Kaiser device connection box for hollow ceilings (item no. 9064-01)

Concrete installation – efficient and cost-effective

The INOTEC SN 9424 impresses with its compact design, which enables particularly straightforward and economical installation in concrete structures. Its reduced size simplifies planning coordination in concrete and significantly reduces both material and labour costs.

The SN 9424 thus offers an efficient, robust and cost-effective solution for applications where safe and easy installation in concrete is a priority.

 

Kaiser device connection box for concrete (item no. 1265-40) >

Safe integration into fire protection ceilings without additional effort

SN 9424 offers significant advantages for installations in fire protection ceilings of classes F30 to F90. In combination with the Kaiser HWD 30 ceiling box, the luminaires can be integrated into corresponding ceiling structures in a standard-compliant and safe manner without compromising the required fire resistance class. Unlike conventional 230 V luminaires, no complex casing is required, which reduces the cost of maintaining functionality and simplifies installation. The tested system solution also ensures reliable operation in the event of a fire, as the ceiling retains its fire resistance without additional measures. This means that even complex fire protection requirements can be met efficiently.

 

< Kaiser ceiling box HWD 30 for fire protection ceilings F30 – F90 (item no. 9464-50)